<LOGO>
FM Transmitter Measurement Report
Created: 2024-08-12 09-19-57
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.20 MHz 5/5, 45 dBuV RTL
Pilot RDS Phase Difference
0.0 kHz 3.9 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
7 kHz 72 kHz 16228 0,6470
Modulation Power
Limit Measuring Tolerance
11,0 dBr 0,2 dBr
MIN AVE MAX % above 11,2 dBr
4,2 dBr 5,48 dBr 6,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" RTL " F211 0 (No PTY) 1 0 0 2 9:19, 12.08.2024
RT
"RTL VIVRENSEMBLE "
AF EON
95.3, 99.8, 100.4, 101.3, 103.6, 103.9, 104.0, 104.1, 104.2, 104.3, 105.0, 105.1, 106.0 MHz -
FM Scope Station: 104.20 MHz, signal: 5/5 (45 dBuV) Max at: 72 kHz MIN: 7 kHz % above 75 kHz: 0,6470 Acquired: 2024/08/12 9:18:54 Total samples: 16228 Equivalent time: 0:13:31 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 6,3 dBr MIN: 4,2 dBr AVE: 5,48 dBr % above 11,2 dBr: 0,0 Last value: 4,5 dBr (2024/08/12 9:18:53) Station: 104.20 MHz, signal: 5/5 (45 dBuV) 09:06 09:08 09:10 09:12 09:14 09:16 09:18 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality